Convolutional Encoder COM-1010 -> BPSK modulator COM-1002 -> BPSK demodulator COM-1001 -> Convolutional Decoder, K=7 COM1009 -> BER measurement COM-1005. Test configuration example: - modulation 8.0 Mbit/s BPSK - error correction K=7 rate = 1/2 - throughput: 4 Mbit/s The bit interleaver is placed in signal generator test mode, whereby a periodic 2047-bit sequence (PRBS-11) is being transmitted. The resulting data stream is BPSK modulated and BPSK demodulated. The end to end BER is measured using the COM-1005 module. The registers settings are as follows: COM-1010: 02 08 COM-1002E: CD CC CC 00 00 00 FF 00 81 00 COM-1001E: 66 66 66 00 00 00 81 00 COM-1009: 82 COM-1005: 00 Proper operation can be verified as follows: (a) using an oscilloscope probe: COM-1001 TP1 is high, indicating demodulator carrier lock COM-1005 TP1 is high, indicating synchronization with the 2047-bit periodic test pattern COM-1005 TP3 is low, showing no bit error pulse. (b) from the ComBlock control center check the BER (COM-1005 status). It will show no bit errors (REG 1 through 4) and the synchronization bit (REG5 bit0) is high. Depending on the demodulated phase ambiguity, the BER can be either 0 (no inverted bit) or 0x0F4240 (all bits inverted).